This product can not be ordered online.
Please call us toll free (800) 789-5613 or at (818) 464-7777;
you can also e-mail our sales department at:
sales@techcctv.com
LVBDS
LARGE VEHICLE-BOMB DETECTION SYSTEM
In the continuing fight against terrorism,
LVBDS is the answer to one of the terrorists' greatest threats
-- MASS DESTRUCTION. LVBDS is an integrated system
solution addressing the need for detection of large
vehicle-bombs with a high vehicle through-put rate. The
LVBDS combines an automated touch-less vehicle sampling system
with Scintrex's patented GC / IMS chemical detection product
and an intuitive icon driven integrated system user interface.
Fully automated for continuous operation, user friendly and
highly reliable, LVBDS can be adapted to suit site-specific
architectural and threat detection requirements.
Uses: Government facilities, Military
installation, Transportation terminals, Industrial sites,
Security establishments, Religious sites, Embassies, Office
towers, Nuclear facilities
S P E C I F I C AT I O N S
VEHICLE SIZE
Standard maximum dimensions:
2.20 m wide x 2.25 m high x 8 m long
7.21 ft wide x 7.37 ft high x 26.2 ft long
Larger sizes available for applications with larger vehicle
and/or cargo containers
THROUGHPUT TIME
Typically less than one minute (dependent on operational
configuration)
EXPLOSIVES DETECTION CAPABILITY
Standard compounds:TNT, NG, AN, EGDN*, o-MNT*, p-MNT*, DMNB*
Dynamite, smokeless powder & other commercially available
explosives
*ICAO marker compounds
ANALYTICAL UNIT SENSITIVITY
Vapours
parts per trillion
Particulates
nanograms to picograms
COMPONENTS
GC / IMS chemical detection units (2)
Air compressor
Vacuum blowers (2)
Air receivers (2)
Vehicle scanning facility consisting of
Tracks, vehicle guide rail set and treadle
Moveable scanning arch
Electrical and control panels (2)
Boom assembly
System integration computer, industrial grade
Electronics rack
OPERATOR FEATURES
Audible and visual alarm annunciation
Fully Automatic Operation
Graphical interface with animation of system operation
Integrated operation, scanning system, doors, optional
sub-systems
Fault condition alarms for all equipment
POWER REQUIREMENTS
Standard equipment
72 kVA, 3 phase, 575 VAC, 60 Hz (includes 2 kVA conditioned
power)
10 kVA, 1 phase, 115 VAC, 60 Hz conditioned, UPS recommended
Optional voltage/frequency powering available
400/230 VAC, 50 Hz
208/115 VAC, 60 Hz
SPACE REQUIREMENTS
Operator room, local or remote, 9 m 2 (100 ft2)
Equipment room, 16 m2 (172 ft2), 3.6 m ceiling clearance
adjacent to scanning area
Vehicle scanning area, 5 m wide, 11.5 m long, 4.5 m ceiling
clearance
(16.4 ft wide, 37.7 ft long, 14.8 ft ceiling clearance)
ENVIRONMENTAL REQUIREMENTS
Operator room, typical indoor office environment
Equipment room, controlled, 25°C ± 5°
Vehicle scanning area, 5°C to 40°C
SYSTEM OPTIONAL COMPONENTS AND DESIGN SERVICES
Integrated vehicle tag based access control system
Integrated weigh scale
Architectural/system design support
Vehicle containment options
Blast containment options
HEALTH HAZARDS
None
ENVIRONMENTAL IMPACT
None
Specifications are subject to change
without notice.
|