Detection method
|

Passive infrared
|
|
Coverage
|

Wide angle 85° wide
21m x 21m (70ft. x 70ft.)
|
Long range
45m x 2.4m (150ft. x 8ft.)
|
|
Detection Zones
|
68 zones
|
22 zones
|
|
Mounting Height
|
1.5m - 3.6m (5 - 12ft.)
|
|
Sensitivity
|
1.6° C at 0.6m/sec. (2.4m mounting
height)
3° F at 2ft./sec. (8ft. mounting
height)
|
|
Detection Speed
|
0.3 - 1.5m/sec. (1 - 5ft./sec.)
|
|
Power input
|
9.5 - 16V DC
|
|
Current draw
|
8mA (normal) /11mA (max.) at 12V DC
|
|
Alarm Period
|
Approx. 2.5 sec.
|
|
Alarm Output
|
N.C. 28V DC 0.2A max.
|
|
Tamper Switch
|
N.C. Opens when cover is removed.
28V DC 0.1A max.
|
|
Pulse count
|
Approx. 20 sec. 2 or 4
|
|
Warm-up Period
|
Approx. 60 sec.
|
|
LED indicator
|
Alarm condition
|
|
RF interference
|
No alarm 30V/m
|
|
Operating temperature
|
-20° C to + 50° C (- 4 °F to +122
°F)
|
|
Environment humidity
|
95% max.
|
|
Weight
|
200g (7.0 oz.)
|
CX-702V (Alarm Memory Version)
 |
|
Polarity
|
Positive
|
Negative (cut jumper)
|
|
Alarm memory
|
armed: open or 5 - 16V DC
|
armed: 0 - 1V DC (grounded)
|
|
Current draw
|
8mA (normal) /16mA (max.) at 12V DC
|
|
CX-702RS (Battery Operated Version) |
|
Power input
|
3 - 9V DC alkaline battery or
lithium battery
|
|
Current draw
|
5µ A (In standby) 10mA (In walktest,
LED on)
|
|
Alarm output
|
Form C 10V DC 0.01A max
|
|
Alarm interval
|
Succeeding signals are not output
even though
detection occurs within 2min. after
the first alarm.
|
|
Tamper switch
|
Form C 28V DC 0.1A max.
|
|
Warm-up period
|
Approx. 90 sec.
|
|
RF interference
|
No alarm 20V/m
|
|
Operating temperature
|