Two color PanTilt camera door
stations, three inside
monitor stations |
 |
Motion-sensor camera via JAW-AZ
adaptor (max. 2) |
 |
Hands-free communication, voice
operated exchange (VOX) |
 |
Instant voice call-in with image |
 |
Press-to-talk (PTT) can override VOX
if necessary |
 |
White LED illuminator turns on in
low-light conditions |
 |
Door call-in LED lights in red or
green |
 |
All Call to all inside stations |
 |
Transfer of door station call |
 |
Optional video (JA-2HCD) or audio
(JA-2SD) sub stations |
 |
Audio door station in lieu of JA
video door station |
 |
Talk LED lit in red while speaking |
 |
Visual monitoring with audio for 30
seconds |
 |
Two door release contacts for
selective control |
 |
Options:
- Foot talk switch
- Manual Talk switch restriction
- Use RY-24L for locally available larger door releases
- Video output to video device (NTSC) |
|
Specifications
|
|
Power Source |
24V DC,
supplied by PS-2420UL
JA-2MCD: 680mA (Max)
JA-2MECD: 750mA (Max)
JA-2HCD: 290mA (Max)
JA-2SD: 120mA (Max)
Use one PS-2420UL per system |
|
Video Monitor |
4" TFT color
LCD |
|
Scanning Lines |
525 Lines |
|
Call-in from Door |
4-stroke
chime from door #1, 2-stroke chime from door #2
Communication from door is hands-free
VOX or Hands-free from interior stations |
|
Internal Calling |
Pre-tone
then voice to inside stations
Hands-free reply from responding station
VOX or Hands-free from calling station |
|
Night Viewing |
Built-in
light is projected up to 12" from camera for view down to 1lux.
Outside area beyond 12" cannot be seen. |
| Door
Release |
Contact
rating: 12V AC, 400mA.
Unit activate contacts of camera that it
is viewing (Selective release) |
| Wiring |
To Door: 2 conductor,
18AWG, non-shielded (Use Aiphone #871802)
Between Inside Units: 4 conductor, 18AWG, non-shielded (Use Aiphone
#871804) |
|
Dimensions (HxWxD) |
JA-2MCD/MECD/2HCD:
8-1/4" x 6-5/16" x 1-5/8"
JA-2SD: 8-1/4" x 3-1/4" x 1-9/16"
JA-DAC: 5-1/8" x 3-7/8" x 1-7/8"
JA-D: 5-1/8" x 3-7/8" x 1-1/8"
|
| Distance |
JA Master to JA-DAC: 330' with 18AWG
JA Master to last JA-2HCD: 330' with 18AWG
JA Master to PS-1820UL: 33' with 18AWG |